Primary power: 115 Vac, 50/60 Hz, 3.5 watts max. (220-240 Vac, 50/60 Hz. optional)
Backup power: 8 AA alkaline batteries (not supplied)for 48 hours continuous operation
Temperature accuracy: ±2°F (±1°C)
Relative humidity range: 0-100%
Relative humidity accuracy: ±3%
Dewpoint range: 32 to 120°F (0 to 50°C)
Dewpoint accuracy: ±2°F (±1°C)
Probe: Combined temperature/ humidity with 6' cable (consult sales for longer cable25' max)
Chart: 6-inch circular chart (supplied with 100 assorted charts)
Chart rotation speeds: User selectable 7 days, 24 hrs, 12 hrs, 6 hrs, 3 hrs, & 1.5 hrs.
Chart rotation: User selectable continuous or single turn
Chart speed accuracy: Better than 1%
Display: Alphanumeric Backlit LCD, 16 characters x 2 lines
Temperature alarm range: -20 to +120° (-30 to +50° C)
Relative humidity alarm range: 0 to 100% RH
Alarm delay range: User selectable: No delay, 10 min., 30 min., 1 hr., & 2 hrs.
Remote alarm connection: Normally open contacts 48 Vac/DC, 0.1 A Resistive load
Mounting: Vertical or horizontal --Free standing or wall mount.
Dimensions: 91Ž4" x 71Ž4" x 23Ž4" (23.5 x 18.4 x 7.0cm)
Operating ambient temp. range: 32 to 120°F (0 degrees to 49°C)
Weight: 4 lbs., 7 oz. (2013g)
To Order (Specify Model Number)
Model Number | Description | Price |
CTH89 | 6" Circular Chart Temperature/Humidity or Dewpoint/Humidity Recorder 110 Vac Operation | $445 |
CTH89-220V | 6" Circular Chart Temperature/Humidity or Dewpoint/Humidity Recorder 220 To 240 Vac Operation | 455 |
CTH89-Pen-Red | Replacement Red Pen | 10 |
CTH89-Pen-Blue | Replacement Blue Pen (Humidity) | 10 |
CTH89-RP | Replacement Probe with 6 Ft. Cable | 145 |
CTH89C-MIX | Mix Box of Assorted Charts (5 of each range) | 19 |
CT89C-(*) | Replacement Charts (Box of 100) See range code below | 19 |
MN1500 | AA Batteries (pack of 2) | 3 |
Each Unit comes with Red and Blue Pens, Box of 100 Assorted Charts, Probe with 6 Ft. Cable,
AC Adapter and Instruction Manual.
Don't forget the accessories! Please refer to the ordering matrix for a complete selection of charts and replacement pens.
(*) Chart Range Code | Record Time | Temperature Range |
E20120F12 | 12 Hours | -20°F to +120°F |
E20120F24 | 24 Hours | |
E20120F7 | 7 Days | |
E2050F12 | 12 Hours | -20°F to +50°F |
E2050F24 | 24 Hours | |
E2050F7 | 7 Days | |
E40110F12 | 12 Hours | +40°F to +11°F |
E40110F24 | 24 Hours | |
E40110F7 | 7 Days | |
E3050C12 | 12 Hours | -30°C to +50°C |
E3050C24 | 24 Hours | |
E3050C7 | 7 Days | |
E3010C12 | 12 Hours | -30°C to +10°C |
E3010C24 | 24 Hours | |
E3010C7 | 7 Days | |
E545C12 | 12 Hours | 5°C to +45°C |
E545C24 | 24 Hours | |
E545C7 | 7 Days |
Recording Charts (use 12-Hr. Chart for 1.5 3 and 6-Hr. Speeds).
Ordering Example: CTH89C-E20120F12 Replacement Chart, 12-Hour record time,
20°F to 120° F Range. Box of 100, $19.
|
|